Never Used Equipment

(REF #: 38-1198)

"Click" on image

EXCHANGERS - SHELL AND TUBE - 2

Built by Enerflex in 2009 and never out into service

Service:

Glycol Heat Exchangers
Duty: TBA
Dimensions: 36" OD x 20'-0" S/S
 

SHELL

TUBE

Design Pressure:

190 PSI

200 PSI

Design Temperature:

400 / -40° F

400 / -40° F

Corrosion Allowance:

0.0625"

 
P.W.H.T:

No

No

Radiography:

100% (RT-1)

 
Heating Surface:

212 Ft.²

Head #1 Material:

SA-516-70N

Head #2 Material:

SA-350LF2 CL1 Blind Flange

Shell Material:

SA-516-70N

Tube Material:

SA-333 Gr.6

Heat Medium Inlet: 3" CL. 300# RFLWN
Heat Medium Outlet: 3" CL. 300# RFLWN
Heat String Inlet: 3" CL. 300# RFLWN
Heat String Outlet: 3" CL. 300# RFLWN
Gas Inlet: 3" CL. 300# RFWN
Gas Outlet: 3" CL. 300# RFWN
Shipping Weight: 5,350 Lbs.
A #'s: A 595225 & 595241
Provincial Registration: Alberta & BC
"U" Stamp: Yes
Status:

Stored in Nisku, Alberta

For more information contact:

Colin Gunning  Tel: (403) 316-0199 / Fax: 18667626098

e-mail.gif (3678 bytes)